The ALC08 Series is the most sought-after unit in the Berner line up at Air Door Distributors. Chosen by designers who are concerned with both aesthetics and protecting the intent of the space when the door is open. The ALC08 series is incredibly quiet and rated min 52 dBA / max 54 dBA for single motor units. The ALC08 series is rated for insect control up to 7 feet high and environmental control up to 8 feet high. The ALC08 series is only 8” in height and in lengths from 30” to 120” wide. Units 30” to 72” long feature a single 1/5 HP motor in a one-piece design while units 84”-120” feature a 1/5 HP two-motor one-piece design. The Berner Architectural Low Profile 8 air curtain with built-in Intelliswitch digital controller (10 fan speeds, start/stop and time delay) and clear satin anodized aluminum cabinet, requires a minimum of 8 ½” clearance above the door. Custom Colors or Stainless Steel available. Available in ambient, electric heat, and steam/hot water configurations.
The ALC08 Series is used at entrances to enhance or replace a vestibule to save energy and maintain comfortable interiors. Simple to install, operate, and maintain and made in the USA. The ALC08 Series is great for customer entry, concessions, drive up windows, walk-in coolers, restaurant & foodservice, retail & office, convenience & grocery and residential. The ALC08 applications include light insect control, reduces dust, dirt and fumes and for temperature control stopping the transfer of warm or cold resulting in significant energy costs.
Architectural Low Profile Series (ALC08) Unheated:
Standard Construction:
- 7 ½” high X 13 ¾” deep
- 1/5 hp motor(s) – ten speeds
- Factory installed intelliswitch digital controller
- Clear satin anodized aluminum exterior (optional: custom color or stainless)
- Wall & Top Mounting
- High efficiency, low noise Pro-V Nozzle
- Optional: Filter (washable)
- Optional: Wi-Fi Controller, works with Berner App
- 5 Year Factory Warranty Ambient
- UL Listed / Canadian C CL listed
- FDA Recommended
- USDA Compliance
Model | Nozzle Width (in) | Max Vel. At Nozzle (fpm) | Avg. Outlet Vel. (fpm) | Air Volume (cfm) | Outlet Vel. Uniformity | Power Rating (kW) | Motor(s) @ hp | Net Wt. (lbs) |
---|---|---|---|---|---|---|---|---|
ALC08-1030A* | 28.00 | 3100 | 1777 | 691 | 89% | 0.18 | 1 @ 1/5 | 33 |
ALC08-1036A* | 35.25 | 3600 | 2116 | 1036 | 92% | 0.32 | 1 @ 1/5 | 38 |
ALC08-1042A* | 41.25 | 3000 | 2115 | 1212 | 93% | 0.32 | 1 @ 1/5 | 43 |
ALC08-1048A* | 47.25 | 2800 | 2104 | 1381 | 94% | 0.32 | 1 @ 1/5 | 48 |
ALC08-1060A* | 59.00 | 3100 | 2053 | 1682 | 95% | 0.32 | 1 @ 1/5 | 57 |
ALC08-1072A* | 72.50 | 3600 | 2058 | 2072 | 95% | 0.32 | 1 @ 1/5 | 64 |
ALC08-2084A* | 84.25 | 3000 | 2072 | 2424 | 93% | 0.64 | 2 @ 1/5 | 86 |
ALC08-2096A* | 86.25 | 2800 | 2066 | 2762 | 94% | 0.64 | 2 @ 1/5 | 96 |
ALC08-2120A* | 119.75 | 3100 | 2023 | 3364 | 95% | 0.64 | 2 @ 1/5 | 114 |
*Voltage Code Required – see below
Note: Operation at 50Hz will generate approximately a 17% reduction in air performance.
Architectural Low Profile Series (ALC08) Electric Heat:
Standard Features:
- 7 ½” high X 13 ¾” deep
- 1/5 hp motor(s) – ten speeds
- Factory installed intelliswitch digital controller
- Clear satin anodized aluminum exterior (optional: custom color or stainless)
- Wall & Top Mounting
- High efficiency, low noise Pro-V Nozzle
- Open helical element with point suspension
- Alternative kW offering – see spec sheets
- Optional: Wi-Fi Controller, works with Berner App
- 2 Year Factory Warranty Electric Heated
- UL Listed / Canadian C CL listed
- FDA Recommended
- USDA Compliance
Model | Nozzle Width (in) | Max Vel. At Nozzle (fpm) | Avg. Outlet Vel. (fpm) | Air Volume (cfm) | Outlet Vel. Uniformity | Power Rating (kW) | Motor(s) @ hp | *Max Electric Capacity (kW) | Heater Output (MBH) | Air Temp. Rise (˚ F) | Net Wt. (lbs) |
---|---|---|---|---|---|---|---|---|---|---|---|
ALC08-1030E* | 28.00 | 3100 | 1777 | 691 | 89% | 0.18 | 1 @ 1/5 | 7.20 | 24.6 | 33˚ | 39 |
ALC08-1036E* | 35.25 | 3600 | 2116 | 1036 | 92% | 0.32 | 1 @ 1/5 | 10.00 | 34.1 | 30˚ | 44 |
ALC08-1042E* | 41.25 | 3000 | 2115 | 1212 | 93% | 0.32 | 1 @ 1/5 | 10.00 | 34.1 | 26˚ | 49 |
ALC08-1048E* | 47.25 | 2800 | 2104 | 1381 | 94% | 0.32 | 1 @ 1/5 | 14.40 | 49.1 | 33˚ | 54 |
ALC08-1060E* | 59.00 | 3100 | 2053 | 1682 | 95% | 0.32 | 1 @ 1/5 | 14.40 | 49.1 | 27˚ | 63 |
ALC08-1072E* | 72.50 | 3600 | 2058 | 2072 | 95% | 0.32 | 1 @ 1/5 | 20.00 | 68.3 | 30˚ | 70 |
ALC08-2084E* | 84.25 | 3000 | 2072 | 2424 | 93% | 0.64 | 2 @ 1/5 | 20.00 | 68.3 | 26˚ | 98 |
ALC08-2096E* | 86.25 | 2800 | 2066 | 2762 | 94% | 0.64 | 2 @ 1/5 | 28.80 | 98.3 | 33˚ | 108 |
ALC08-2120E* | 119.75 | 3100 | 2023 | 3364 | 95% | 0.64 | 2 @ 1/5 | 28.80 | 98.3 | 27˚ | 126 |
Notes:
1. Operation at 50 Hz will generate approximately a 17” reduction in performance
2. Performance data based on unheated units.
3. Single Point Power Connection – consult Air Door Distributors.
Architectural Low Profile Series (ALC08) Hot Water Heated:
Standard Features:
- 7 ½” high X 13 ¾” deep
- 1/5 hp motor(s) – ten speeds
- Factory installed intelliswitch digital controller
- Clear satin anodized aluminum exterior (optional: custom color or stainless)
- Wall & Top Mounting
- High efficiency, low noise Pro-V Nozzle
- Optional: Filter (washable)
- Optional: Wi-Fi Controller, works with Berner App
- 2 Year Factory Warranty Electric Heated
- FDA Recommended
- USDA Compliance
Coli Features:
- Galvanized steel casings
- 5/8” copper tube with .035” wall
- Aluminum Fins
-
Leak tested at 450 PSI
Model | Nozzle Width (in) | Max Vel. At Nozzle (fpm) | Avg. Outlet Vel. (fpm) | Air Volume (cfm) | Outlet Vel. Uniformity | Power Rating (kW) | Motor(s) @ hp | Coil Output (MBH) | Entering / Leaving Water Temp. (˚ F) | Water Flow (GPM) | Fluid Pressure Drop (FT.WG.) | Air Temp. Rise (˚ F) | Net Wt. (lbs) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ALC08-1030W* | 28.00 | 3100 | 1777 | 691 | 89% | 0.18 | 1 @ 1/5 | 18.8 | 180˚/167˚ | 3.0 | 0.6 | 25˚ | 56 |
ALC08-1036W* | 35.25 | 3600 | 2116 | 1036 | 92% | 0.32 | 1 @ 1/5 | 28.1 | 180˚/168˚ | 5.0 | 1.7 | 25˚ | 64 |
ALC08-1042W* | 41.25 | 3000 | 2115 | 1212 | 93% | 0.32 | 1 @ 1/5 | 32.8 | 180˚/167˚ | 5.0 | 1.8 | 25˚ | 72 |
ALC08-1048W* | 47.25 | 2800 | 2104 | 1381 | 94% | 0.32 | 1 @ 1/5 | 38.5 | 180˚/167˚ | 6.0 | 2.6 | 25˚ | 80 |
ALC08-1060W* | 59.00 | 3100 | 2053 | 1682 | 95% | 0.32 | 1 @ 1/5 | 46.3 | 180˚/163˚ | 5.5 | 2.3 | 25˚ | 95 |
ALC08-1072W* | 72.50 | 3600 | 2058 | 2072 | 95% | 0.32 | 1 @ 1/5 | 56.8 | 180˚/161˚ | 6.0 | 2.9 | 25˚ | 107 |
ALC08-2084W* | 84.25 | 3000 | 2072 | 2424 | 93% | 0.64 | 2 @ 1/5 | 67.3 | 180˚/160˚ | 7.0 | 4 | 25˚ | 134 |
ALC08-2096W* | 86.25 | 2800 | 2066 | 2762 | 94% | 0.64 | 2 @ 1/5 | 76.8 | 180˚/159˚ | 7.5 | 4.8 | 25˚ | 150 |
ALC08-2120W* | 119.75 | 3100 | 2023 | 3364 | 95% | 0.64 | 2 @ 1/5 | 95.6 | 180˚/158˚ | 9.0 | 7.3 | 26˚ | 178 |
Notes:
1. Operation at 50 Hz will generate a 17% reduction in performance.
2. Performance date based on unheated units.
3. Coil performance based on 65˚F entering air temperature.
4. Standard connection same end supply/return.
5. Coil should be field supplied with a solenoid valve that energizes only when air curtains is energized. Consideration must be taken for freeze protection when necessary.
6. Maximum leaving air temperature shall not exceed 120˚F.
7. Consult Air Door Distributors for alternative entering air & water temperatures, GPM’s, or vertical mounted units.
Architectural Low Profile Series (ALC08) Steam Heated:
Standard Features:
- 7 ½” high X 13 ¾” deep
- 1/5 hp motor(s) – ten speeds
- Factory installed intelliswitch digital controller
- Clear satin anodized aluminum exterior (optional: custom color or stainless)
- Wall & Top Mounting
- High efficiency, low noise Pro-V Nozzle
- Optional: Filter (washable)
- Optional: Wi-Fi Controller, works with Berner App
- 2 Year Factory Warranty Electric Heated
- FDA Recommended
- USDA Compliance
Coli Features:
- Galvanized steel casings
- 5/8” copper tube with .035” wall
- Aluminum Fins
-
Leak tested at 450 PSI
Model | Nozzle Width (in) | Max Vel. At Nozzle (fpm) | Avg. Outlet Vel. (fpm) | Air Volume (cfm) | Outlet Vel. Uniformity | Power Rating (kW) | Motor(s) @ hp | Coil Output (MBH) | Inlet Pressure (PSIG) | Condensate (lbs/hr) | Air Temp. Rise (˚ F) | Net Wt. (lbs) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
ALC08-1030S* | 28.00 | 3100 | 1777 | 691 | 89% | 0.18 | 1 @ 1/5 | 31.8 | 5 | 32.8 | 42˚ | 56 |
ALC08-1036S* | 35.25 | 3600 | 2116 | 1036 | 92% | 0.32 | 1 @ 1/5 | 44.4 | 5 | 48.8 | 39˚ | 64 |
ALC08-1042S* | 41.25 | 3000 | 2115 | 1212 | 93% | 0.32 | 1 @ 1/5 | 52.5 | 5 | 54.1 | 40˚ | 72 |
ALC08-1048S* | 47.25 | 2800 | 2104 | 1381 | 94% | 0.32 | 1 @ 1/5 | 60.5 | 5 | 62.3 | 40˚ | 80 |
ALC08-1060S* | 59.00 | 3100 | 2053 | 1682 | 95% | 0.32 | 1 @ 1/5 | 75.3 | 5 | 77.7 | 41˚ | 95 |
ALC08-1072S* | 72.50 | 3600 | 2058 | 2072 | 95% | 0.32 | 1 @ 1/5 | 93.2 | 5 | 96.1 | 41˚ | 107 |
ALC08-2084S* | 84.25 | 3000 | 2072 | 2424 | 93% | 0.64 | 2 @ 1/5 | 109.4 | 5 | 112.7 | 41˚ | 134 |
ALC08-2096S* | 86.25 | 2800 | 2066 | 2762 | 94% | 0.64 | 2 @ 1/5 | 125.2 | 5 | 129.0 | 41˚ | 150 |
ALC08-2120S* | 119.75 | 3100 | 2023 | 3364 | 95% | 0.64 | 2 @ 1/5 | 154.8 | 5 | 159.6 | 42˚ | 178 |
Notes:
1. Operation at 50 Hz will generate a 17% reduction in performance.
2. Performance date based on unheated units.
3. Coil performance based on 65˚F entering air temperature.
4. Standard connection same end supply/return.
5. Coil should be field supplied with a solenoid valve that energizes only when air curtains is energized. Consideration must be taken for freeze protection when necessary.
6. Maximum leaving air temperature shall not exceed 120˚F.
7. Consult Air Door Distributors for alternative steam pressures or vertically mounted units.