Skip to content

Commercial Low Profile 8 Series (CLC08)

For mounting heights to 8′ (environmental separation) and 7′ (insect control)

commercial low profile 8 series berner air curtains

The Commercial Low Profile 8 Series by Berner International is extremely popular here at Air Door Distributors. The CLC08 Series is noticeably quiet and rated at min 53 dBA/max 54 dBA for single motors units. The CLC08 Series is rated for insect control up to 7 feet high and environmental control up to 8 feet high. The CLC08 Series is only 8.5” in height and requires a 9.5” clearance above door and in lengths from 30” to 120” wide. Units 30’ to 72” long feature a single 1/5 HP motor in a one-piece design while units 84” to 120” feature a 1/5 HP two-motor one piece design. The Berner Commercial Low Profile 8 Series is equipped with back mounting plate or easy top mounting and a factory-installed fan 2-speed switch.  It is available in either a white or black powder-coated exterior with optional: custom color RAL colors 1000-9023 or stainless steel. 

The CLC08 Series is used at entrances to enhance or replace a vestibule to save energy and maintain comfortable interiors. These air curtains are simple in install, operate, maintain, and made in the USA. The CLC8 Series is great for customer entry, concessions, drive-up windows, walk-in coolers, restaurants & food service, retail & office, convenience and grocery, and residential. The CLC08 Series applications include light insect control, reduces dust, dirt, and fumes and for temperature control stopping the transfer of warm or cold resulting in significant energy costs.

Commercial Low Profile 8 Unheated Air Curtains:

clc08 unheated

Standard Construction: 

  • 8 1/2” high x 13 1/2” deep
  • 1/5 hp two speed motor(s)
  • Factory installed fan speed switch
  • White or black powder coated exterior (Optional: Custom Color or Stainless)
  • Wall & Top Mounting
  • Optional: Filter (washable)
  • 5 Year Factory Warranty Ambient 
  • UL listed / Canadian C UL Listed
  • MADE IN USA

Model Nozzle Width (in) Max Vel. At Nozzle (fpm) Avg. Outlet Vel. (fpm) Air Volume (cfm) Outlet Vel. Uniformity Power Rating (kW) Motor(s) @ hp Net Wt. (lbs)
CLC08-1030A* 27.50 3071 1478 670 89% 0.32 1 @ 1/5 36
CLC08-1036A* 34.62 3567 1760 1005 92% 0.32 1 @ 1/5 41
CLC08-1042A* 40.62 3388 1755 1176 93% 0.32 1 @ 1/5 45
CLC08-1048A* 46.62 3226 1742 1340 94% 0.32 1 @ 1/5 48
CLC08-1060A* 58.13 2940 1702 1632 95% 0.32 1 @ 1/5 56
CLC08-1072A* 71.37 2870 1707 2010 95% 0.32 1 @ 1/5 64
CLC08-2084A* 83.50 3388 1707 2351 93% 0.64 2 @ 1/5 90
CLC08-2096A* 95.50 3226 1701 2679 94% 0.64 2 @ 1/5 98
CLC08-2108A* 107.00 3226 1684 2971 94% 0.64 2 @ 1/5 105
CLC08-2120A* 118.50 2940 1670 3263 95% 0.64 2 @ 1/5 113

*Voltage Code Required – see below
Note: Operation at 50Hz will generate approximately a 17% reduction in air performance.

 

Commercial Low Profile 8 Electric Heat Air Curtains:

berner commercial low profile 8 series electric heated air curtain

Standard Construction:

  • 8 1/2” high x 13 1/2” deep
  • 1/5 hp two speed motor(s)
  • Factory installed fan speed/heat switch 
  • White or black powder coated exterior (Optional: Custom Color or Stainless)
  • Wall & Top Mounting
  • Open helical element with point suspension
  • Thermal overload protection
  • Galvanized steel frame
  • Alternate kW
  • Optional: Filter (washable)
  • 2 Year Factory Warranty Ambient 
  • UL listed / Canadian C UL Listed
  • MADE IN USA

Model Nozzle Width (in) Max Vel. At Nozzle (fpm) Avg. Outlet Vel. (fpm) Air Volume (cfm) Outlet Vel. Uniformity Power Rating (kW) Motor(s) @ hp *Max Electric Capacity (kW) Heater Output (MBH) Air Temp. Rise (˚ F) Net Wt. (lbs)
CLC08-1030E* 27.50 3071 1478 670 89% 0.32 1 @ 1/5 7.20 24.6 34˚ 42
CLC08-1036E* 34.62 3567 1760 1005 92% 0.32 1 @ 1/5 10.00 34.1 31˚ 48
CLC08-1042E* 40.62 3388 1755 1176 93% 0.32 1 @ 1/5 10.00 34.1 27˚ 53
CLC08-1048E* 46.62 3226 1742 1340 94% 0.32 1 @ 1/5 14.40 49.1 34˚ 58
CLC08-1060E* 58.13 2940 1702 1632 95% 0.32 1 @ 1/5 14.40 49.1 28˚ 67
CLC08-1072E* 71.37 2870 1707 2010 95% 0.32 1 @ 1/5 20.00 68.3 31˚ 77
CLC08-2084E* 83.50 3388 1707 2351 93% 0.64 2 @ 1/5 20.00 68.3 27˚ 105
CLC08-2096E* 95.50 3226 1701 2679 94% 0.64 2 @ 1/5 28.80 98.3 34˚ 115
CLC08-2108E* 107.00 3226 1684 2971 94% 0.64 2 @ 1/5 28.80 98.3 30˚ 123
CLC08-2120E* 118.50 2940 1670 3263 95% 0.64 2 @ 1/5 28.80 98.3 28˚ 137

Notes:
1. Operation at 50 Hz will generate approximately a 17% reduction in air performance.
2. Performance data based on unheated units.
3. Consult Air Door Distributors for vertically mounted units.

Commercial Low Profile 8 Hot Water Air Curtains:

Standard Construction:

  • 8 1/2” high x 13 1/2” deep
  • 1/5 hp two speed motor(s)
  • Factory installed fan speed switch
  • White or black powder coated exterior (Optional: Custom Color or Stainless)
  • Wall & Top Mounting
  • Optional: Filter (washable)
  • Coil Features
    • Galvanized steel casing 
    • 5/8” copper tube with .035” wall
    • Aluminum fins
    • Leak tested at 450 PSI
  • 2 Year Factory Warranty Ambient 
  • UL listed / Canadian C UL Listed
  • MADE IN USA

Model Nozzle Width (in) Max Vel. At Nozzle (fpm) Avg. Outlet Vel. (fpm) Air Volume (cfm) Outlet Vel. Uniformity Power Rating (kW) Motor(s) @ hp Coil Output (MBH) Entering / Leaving Water Temp. (˚ F) Water Flow (GPM) Fluid Pressure Drop (FT.WG.) Air Temp. Rise (˚ F) Net Wt. (lbs)
CLC08-1036W* 34.62 3567 1760 1005 92% 0.32 1 @ 1/5 27.7 180˚/169˚ 5.0 1.7 25˚ 67
CLC08-1042W* 40.62 3388 1755 1176 93% 0.32 1 @ 1/5 32.4 180˚/167˚ 5.0 1.8 25˚ 74
CLC08-1048W* 46.62 3226 1742 1340 94% 0.32 1 @ 1/5 36.8 180˚/165˚ 6.0 1.8 25˚ 80
CLC08-1060W* 58.13 2940 1702 1632 95% 0.32 1 @ 1/5 44.8 180˚/162˚ 5.5 1.9 25˚ 94
CLC08-1072W* 71.37 2870 1707 2010 95% 0.32 1 @ 1/5 56.1 180˚/161˚ 6.0 2.9 25˚ 107
CLC08-2084W* 83.50 3388 1707 2351 93% 0.64 2 @ 1/5 6.5 180˚/161˚ 7.0 4.0 26˚ 138
CLC08-2096W* 95.50 3226 1701 2679 94% 0.64 2 @ 1/5 74.8 180˚/158˚ 7.5 4.1 25˚ 152
CLC08-2108W* 107.00 3226 1684 2971 94% 0.64 2 @ 1/5 85.0 180˚/158˚ 7.5 5.6 26˚ 164
CLC08-2120W* 118.50 2940 1670 3263 95% 0.64 2 @ 1/5 94.3 180˚/158˚ 9.0 7.3 26˚ 177

Notes:
1. Operation at 50 Hz will generate approximately a 17% reduction in performance.
2. Performance data based on unheated units.
3. Coil performance based on 65°F entering air temperature.
4. Standard connection same end supply/return.
5. Coil should be field supplied with a solenoid valve that energizes only when air curtain is energized. Consideration must be taken for freeze protection when necessary.
6. Maximum leaving air temperature shall not exceed 120°F.
7. Consult Air Door Distributors for alternate entering air & water temperatures, GPM’s, or vertically mounted units.

Commercial Low Profile 8 Steam Heated Air Curtains:

Standard Construction:

  • 8 1/2” high x 13 1/2” deep
  • 1/5 hp two speed motor(s)
  • Factory installed fan speed switch
  • White or black powder coated exterior (Optional: Custom Color or Stainless)
  • Wall & Top Mounting
  • Optional: Filter (washable)
  • Coil Features
    • Galvanized steel casing 
    • 5/8” copper tube with .035” wall
    • Aluminum fins
    • Leak tested at 450 PSI
  • 2 Year Factory Warranty Ambient 
  • UL listed / Canadian C UL Listed
  • MADE IN USA

Model Nozzle Width (in) Max Vel. At Nozzle (fpm) Avg. Outlet Vel. (fpm) Air Volume (cfm) Outlet Vel. Uniformity Power Rating (kW) Motor(s) @ hp Coil Output (MBH) Inlet Pressure (PSIG) Condensate (lbs/hr) Air Temp. Rise (˚ F) Net Wt. (lbs)
ALC08-1036S* 34.62 3567 1760 1005 92% 0.32 1 @ 1/5 42.0 5 43.3 42˚ 67
ALC08-1042S* 40.62 3388 1755 1176 93% 0.32 1 @ 1/5 49.7 5 51.2 40˚ 74
ALC08-1048S* 46.62 3226 1742 1340 94% 0.32 1 @ 1/5 57.2 5 58.9 40˚ 80
ALC08-1060S* 58.13 2940 1702 1632 95% 0.32 1 @ 1/5 71.2 5 73.4 41˚ 94
ALC08-1072S* 71.37 2870 1707 2010 95% 0.32 1 @ 1/5 88.1 5 90.8 42˚ 107
ALC08-2084S* 83.50 3388 1707 2351 93% 0.64 2 @ 1/5 103.3 5 106.5 40˚ 138
ALC08-2096S* 95.50 3226 1701 2679 94% 0.64 2 @ 1/5 118.3 5 121.9 40˚ 152
ALC08-2108S* 107.00 3226 1684 2971 94% 0.64 2 @ 1/5 133.1 5 137.2 41˚ 164
ALC08-2120S* 118.50 2940 1670 3263 95% 0.64 2 @ 1/5 146.3 5 150.8 41˚ 177

Notes:
1. Operation at 50 Hz will generate approximately a 17% reduction in performance.
2. Performance data based on unheated units.
3. Coil performance based on 65°F entering air temperature.
4. Standard connection same end supply/return.
5. Coil should be field supplied with a solenoid valve that energizes only when air curtain is energized. Consideration must be taken for freeze protection when necessary.
6. Maximum leaving air temperature shall not exceed 120°F.
7. Consult Air Door Distributors for alternate entering air & water temperatures, GPM’s, or vertically mounted units.